Products

2U SingleP2G-6510P


OUTPUT WATTAGE

510W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

240x100x70(mm)

9.45x3.94x2.76(inch)

INPUT SPEC

VOLTAGE: 103 ~ 264 VAC
FREQUENCY: 47~63HZ
INPUT CURRENT: 8A/4A AT 110/220VAC
INRUSH CURRENT: 55/110A AT 110/220VAC

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
5V 5 33 ± 5% ± 1% 60mV
12V 2.5 32 ± 5% ± 1% 100mV
-5V 0.05 0.8 ± 5% ± 1% 120mV
-12V 0.1 1 ± 5% ± 1% 150mV
3.3V 1 28 ± 5% ± 1% 50mV
+5VSB 0.1 2 ± 5% ± 1% 60mV
REMARKS: (1) TOTAL CURRENT OF 5V & 3.3V NOT EXCEED 45A (2) TOTAL POWER OUTPUT NOT EXCEED 510W

FEATURES

*Active PFC (full range), MEET IEC-1000-3-2 CLASS D
*12V Max. Current :32A
*TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃.
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
*OVER POWER PROTECTION
*OVER VOLTAGE PROTECTION
*OVER CURRECT PROTECTION
*SHORT CIRCUIT PROTECTION
*SAFETY: UL, CSA, TUV
*Remote on/off control
*Cooling: ONE 60 mm DC Fan
*3.3V / 5V Remote sensing
*Serial ATA optional

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module