Products

2U RedundantG1W2-5AE0G2V


   

OUTPUT WATTAGE

1500W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

300x101.2x84(mm)

11.81x3.98x3.31(inch)

INPUT SPEC

VOLTAGE: 104~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT (PER POWER MODULE):15A/10.5A FOR 115/230VAC
INRUSH CURRENT (PER POWER MODULE):40A/80A MAX. FOR 115/230VAC (at 25 degrees ambient cold start for each power unit)
PFC: Up to the target of 95% @115/230VAC, full load

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1 36 ±5% ±1% 50mV
+12V 2 124 ±5% ±1% 120mV
-12V 0 0.8 ±10% ±1% 120mV
+3.3V 1 36 ±5% ±1% 50mV
+5VSB 0.1 3.5 ±5% ±1% 50mV
* +5V AND +3.3V TOTAL OUTPUT MAX: 210W
* Total power: 1500W (MAX) @ 230VAC / 1200W (MAX) @ 115VAC

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
* HOLD UP TIME:14mS MIN.
* EFFICIENCY:SHALL BE 82% AT 230V AND FULL LOADING
* OVER POWER PROTECITON: 110~160%
* OVER VOLTAGE PROTECTION:+3.3V→+3.9V~+4.3V,+5V→+5.9V~+6.5V,+12V→+13.3V~+15V
* OVER CURRENT PROTECTION: 110~150%
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
* REMOTE ON/OFF CONTROL
* EMI NOISE FILTER: FCC CLASS B , CISPR 22 CLASS B
* MEET EN61000-3-2 CLASS D (ACTIVE PFC)
* SAFETY:TO MEET UL, CUL, TUV, CCC

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module