Products

Mini 1U SingleP1P-2600K


 

OUTPUT WATTAGE

600W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

170x81.5x40.3(mm)

6.69x3.21x1.59(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:8.5A (RMS) FOR 115 VAC / 4.5A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC / 80A MAX. FOR 230 VAC
PFC: UP TO THE TARGET OF 95% @115/230VAC, FULL LOAD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 1 50 ±5% ±1% 120mV
+5VSB 0.05 3 ±5% ±1% 50mV

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃, OPERATING -20℃~80℃
* HOLD UP TIME:12mS MINIMUM AT 75% OF MAX. LOAD & NOMINAL INPUT VOLTAGE
* EFFICIENCY:The maximum power supply system efficiency shall be 91%, measured at nominal input voltage 230V and full loading
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION
* OVER CURRENT PROTECTION
* SHORT CIRCUIT PROTECTION
* EMI NOISE FILTER : FCC CLASS A, CISPR22 CLASS A
* SAFETY: TO MEET UL, CUL, TUV, CCC * RFI/EMI: FCC CLASS A, CISPR 22 CLASS A
* REMOTE ON/OFF CONTROL
* COOLING: ONE 40mm DC FANS


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

 DOWNLOAD
CB
CE(Radiation)
FCC
TUV
TUV

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module