【Mini Redundant】MRS-6500P
500W
Server ,Workstation ,Storage System ,IPC
260x150x84(mm)
10.24x5.91x3.31(inch)
FREQUENCY: 50~60Hz +/- 3Hz INPUT CURRENT:4.5A(RMS)FOR 230VAC/9A(RMS)FOR 115VAC INRUSH CURRENT:65A MAX. FOR 115 VAC PER MODULE 125A MAX. FOR 230 VAC PER MODULE
* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃ * HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute * EFFICIENCY:65% TYPICAL,AT FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION:+5V→ 5.7V~6.5V,+3.3V→ 3.9V~4.5V ,+12V→ 13.3V~14.5V, 5VSB→ 5.7V~6.5V * OVER CURRENT PROTECTION:110~150% MAX * SAFETY:UL-1950-1 , CSA-C22.2 NO.60950-1-03 , TUV EN-60950-1, CB IEC 60950-1 * REMOTE ON / OFF CONTROL * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL,I2C * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.