Products

Easy SwapM1W1-5E00V3H


 

OUTPUT WATTAGE

1400W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC ,Blade server ,PCs ,Communication

DIMENSION

320x98.4x40(mm)

12.6x3.87x1.57(inch)

INPUT SPEC

VOLTAGE: 115 ~ 240 VAC FULL RANGE (With ±10% tolerance)
FREQUENCY: 47 ~ 63 Hz
INPUT CURRENT: 15/10 AMPS MAXIMUM AT ANY LOW/HIGH
RANGE INPUT VOLTAGE
INRUSH CURRENT: 15/30 AMPS @115/230 VAC.
(HIGH FREQUENCY PEAK AMPLITUDES LASTING LESS
THAN 200US(AT 25 DEGREES AMBIENT COLD START
FOR EACH POWER UNIT)

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1 24 ± 5% ± 1% 50mV
+12V 2 116 ± 5% ± 1% 120mV
-12V 0 0.5 ± 5% ± 1% 120mV
+3.3V 1 24 ± 5% ± 1% 50mV
+5VSB 0.1 4.0 ± 5% ± 1% 50mV
* POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 135W
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 1400W FOR 180~264VAC.
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 1200W FOR 103~132VAC.

FEATURES

* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃; OPERATING TEMPERATURE FROM 0℃ SHOULD START FROM AC 90V
* HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT 115 VAC INPUT VOLTAGE AND 1000W OUTPUT LOAD
* EFFICIENCY: TYPICAL 84% AT 115V, 86% AT 230V, FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 550 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION: 110~150%
* OVER VOLTAGE PROTECTION: +3.3V→3.7~4.1V, +5V→5.7~6.5V, +12V→12.8~13.9V
* OVER CURRENT PROTECTION: THE POWER SUPPLY SHALL LATCH OFF IF THE +12V OUTPUT CURRENTS ARE OVER IT’S LIMITATION. THE LIMITED CURRENT IS OVER 110~150% FOR EACH POWER MODULE.
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V OUTPUT TO DC RETURN SHALL CAUSE NO DAMAGE AND POWER SUPPLY LATCH, -12V SHORT CIRCUIT TO DC RETURN SHALL CAUSE NO DAMAGE.
* SAFETY: MEET UL, CUL, TÜV
* MEET IEC-1000-3-2 CLASS D

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 