Products

PS2+PSM-5760V


   

OUTPUT WATTAGE

760W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

160x150x86(mm)

6.3x5.91x3.39(inch)

INPUT SPEC

VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 12 A ( RMS ) FOR 115VAC /
6A ( RMS ) FOR 230VAC
INRUSH CURRENT: 20A MAX. FOR 115 VAC /
40A MAX. FOR 230 VAC
PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 25 ±5% ±1% 50mV
+12V 1 55 ±5% ±1% 120mV
-12V 0 0.8 ±5% ±1% 120mV
+3.3V 0.5 25 ±5% ±1% 50mV
+5VSB 0.1 3.5 ±5% ±1% 50mV

FEATURES

* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃
* HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* HUMIDITY: OPERATING:20%-80%, NON-OPERATING:10%-90%
* EFFICIENCY: TYPICAL 80-85% AT 25℃ 115V FULL LOAD
* OVER POWER PROTECTOIN: 130%~170%
* OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.8~6.7V, +12V→13.2~15V
* OVER CURRENT PROTECTION: +3.3V→29.7~40.2A, +5V→29.7~40.2A, +12V→63.7~86.2A
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
* RESTART AFTER PROTECTION: IF THE PSU IS USING AC POWER SWITCH TO CONTROL ON/OFF, IT HAS TO BE SWITCHED OFF AT LEAST FOR 5 SECONDS TO RESTART THE UNIT
* SAFETY: TO MEET UL, CUL, TUV, CCC
* COOLING: ONE 60 mm DC FAN


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module