【Mini Redundant】MRW-5450V4V
450W
Server ,Workstation ,Storage System
185x150x86(mm)
7.28x5.91x3.39(inch)
VOLTAGE: 90 ~ 264 VAC FULL RANGE. FREQUENCY: 47 ~ 63 Hz. STEADY-STATE CURRENT: 7/3A AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 25A MAX. FOR 110 VAC , 50A MAX. FOR 220 VAC (AT 25 DEGREE C AMBIENT COLD START) PFC: UP TO THE TARGET OF 95% @110V, FULL LOAD
* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃; STORAGE TEMPERATURE: -20℃ – 80℃ * HOLD UP TIME: 16mS MINIMUM AT NOMINAL INPUT VOLTAGE * EFFICIENCY: TYPICAL >80% AT 115V, 25%~100% MAX LOAD * LEAKAGE CURRENT: 3.5 mA. MAX. AT NOMINAL VOLTAGE 250VAC * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER POWER PROTECTION: 110%~160% * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.5~6.5V, +12V→13.2~15.6V * OVER CURRENT PROTECTION: +3.3V→27.5~37.5A, +5V→ 27.5~37.5A, +12V→45.1~65.6A * SHORT CIRCUIT PROTECTION: +12V, -12V, +5VSB * SAFETY: TO MEET UL, TUV, CB, CCC, RFI/EMI STANDARDS * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B * REMOTE ON/OFF CONTROL * I2C FEATURES (OPTIONAL) *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module