Products

Micro RedundantM1K2-2C00V4Q


     

OUTPUT WATTAGE

1200W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

450x54.5x84.6(mm)

17.72x2.15x3.33(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:15A(RMS)FOR 115VAC / 8A(RMS)FOR 230VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC can reach the target of 95% @110V,full load, following the standard Of EN 61000-3-2

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V1 0 25 ±5% ±1% 120mV
+12V2 0 25 ±5% ±1% 120mV
+12V3 0 25 ±5% ±1% 120mV
+12V4 0 25 ±5% ±1% 120mV
+5VSB1 0 1 ±5% ±1% 50mV
+5VSB2 0 1 ±5% ±1% 50mV
+5VSB3 0 1 ±5% ±1% 50mV
+5VSB4 0 1 ±5% ±1% 50mV
* +5VSB1,+5VSB2,+5VSB3,+5VSB4 Total Max:15W * Total output power not exceed:1200W (MAX)

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
* EFFICIENCY:TYPICAL 83% AT 115V, 12V/83A 5VSB/0.1A; TYPICAL 86% AT 230V, 12V/83A 5VSB/0.1A
* OVER POWER PROTECTION
* OVER VOLTAGE PROTECTION
* SHORT CIRCUIT PROTECTION
* SAFETY:TO MEET UL, CUL, TUV, CCC


* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 