Products

Search:

Mini RedundantMRS-6500P


 

OUTPUT WATTAGE

500W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

260x150x84(mm)

10.24x5.91x3.31(inch)

INPUT SPEC

FREQUENCY: 50~60Hz +/- 3Hz
INPUT CURRENT:4.5A(RMS)FOR 230VAC/9A(RMS)FOR 115VAC
INRUSH CURRENT:65A MAX. FOR 115 VAC PER MODULE
125A MAX. FOR 230 VAC PER MODULE

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 2 50 ± 5% ± 1% 50mV
+12V 2 25 ± 5% ± 1% 120mV
-5V 0 1 ±10% ± 1% 100mV
-12V 0 1 ±10% ± 1% 120mV
+3.3V 1 28 ± 5% ± 1% 50mV
+5VSB 0 2 ± 5% ± 1% 50mV
REMARK: 1. +5V AND +3.3V TOTAL MAX: 60A
2. +5V, +3.3V AND +12V TOTAL MAX: 485W

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
* HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
* EFFICIENCY:65% TYPICAL,AT FULL LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION:+5V→ 5.7V~6.5V,+3.3V→ 3.9V~4.5V ,+12V→ 13.3V~14.5V, 5VSB→ 5.7V~6.5V
* OVER CURRENT PROTECTION:110~150% MAX
* SAFETY:UL-1950-1 , CSA-C22.2 NO.60950-1-03 , TUV EN-60950-1, CB IEC 60950-1
* REMOTE ON / OFF CONTROL
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL,I2C

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module