Products

Open FrameQ1N-3400K


     

OUTPUT WATTAGE

400W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

199x92x43(mm)

7.83x3.62x1.69(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:6A (RMS) FOR 115 VAC
3A (RMS) FOR 230 VAC
INRUSH CURRENT:30 AMPS @ 230 VAC
(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 5 ±5% ±1% 50mV
+12V 1 33 ±5% ±1% 120mV
+5VSB 0.1 3 ±5% ±1% 50mV
* +5V: option
* TOTAL POWER: 400W(MAX)

FEATURES

‧TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
‧HOLD UP TIME:16mS MINIMUM AT 115V FULL LOAD
‧EFFICIENCY:90% TYPICAL,AT FULL LOAD 230V
‧REMOTE ON/OFF CONTROL
‧LEAKAGE CURRENT: INPUT LEAKAGE CURRENT FROM LINE TO GROUND WILL BE LESS THAN 3.5MA RMS. MEASUREMENT WILL BE MADE AT 240 VAC AND 60HZ.
‧POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
‧OVER POWER PROTECTION:110~160% MAX
‧OVER VOLTAGE PROTECTION: +12V→ 13.2~15V
‧SHORT CIRCUIT PROTECTION: +12V, +5VSB
‧SAFETY : TO MEET UL, CUL, TUV, CCC


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

 DOWNLOAD
CB
CCC
TUV

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module