Products

N+1 RedundantMTW4-5H80V3V


   

OUTPUT WATTAGE

1780W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC ,Communication

DIMENSION

300x101.2x166(mm)

11.81x3.98x6.54(inch)

INPUT SPEC

VOLTAGE: 90V ~ 264VAC (WITH ± 10% TOLERANCE)
FREQUENCY: 47Hz ~ 63Hz
INPUT CURRENT: INPUT CURRENT:27/12A MAX AT ANY
LOW/HIGH INPUT VOLTAGE
INRUSH CURRENT: 40A MAX. FOR 115 VAC PER MODULE;
60A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC
61000-3-2

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1.5 86 ±5% ±1% 50mV
+12V 6 135 ±5% ±1% 120mV
-12V 0.1 1.6 ±5% ±1% 120mV
+3.3V 1.5 97 ±5% ±1% 120mV
+5VSB 0.3 7 ±5% ±1% 70mV
* +5V AND +3.3V TOTAL OUTPUT MAX: 540W

FEATURES

* TEMPERATURE RANGE: OPERATING: 0℃~ 45℃, STORAGE: -20℃~ 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
* EFFICIENCY: TYPICAL >80% AT 115V, 30~100% MAX LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION: 110~160%
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.9~4.7V, +12V→12.8~13.9V
* OVER CURRENT PROTECTION: +5V, +12V, +3.3V, LIMITED CURRENT IS OVER 110~160% FOR EACH OUTPUT CURRENT AT EACH POWER MODULE
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
* WARMING METHOD: BUZZER SOUND, TTL
* HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
* BALANCE LOAD SHARING DESIGN
* REMOTE ON/OFF CONTROL
* SAFETY: TO MEET UL, CUL, TUV, CCC


* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

 DOWNLOAD
DRAWING

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module