Products

Open FrameG1X2-5060V


 

OUTPUT WATTAGE

60W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

190x106x39.5(mm)

7.48x4.17x1.56(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC /
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC /
70A MAX. FOR 230 VAC

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 6 ±5% ±1% 50mV
+12V 0.1 5 ±5% ±1% 120mV
-12V 0 0.3 ±10% ±1% 120mV
+3.3V 0 6 ±5% ±1% 50mV
+5VSB 0 3 ±5% ±1% 50mV
* +5V AND +3.3V TOTAL MAX: 30W
* MAXIMUM OUTPUT MAX: 60W

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~70℃, STORAGE –20℃~80℃
* HOLD UP TIME: WHEN AC SOURCE SHUTDOWN DC OUTPUT MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE(AC115V AT 80% OF FULL LOAD)
* EFFICIENCY:76% (+/-2%) AT 115VAC/230VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS
* OVER POWER PROTECTION: 120~170%
* OVER VOLTAGE PROTECTION: +3.3V→3.6V~4.3V +5V→5.6V~6.5V; +12V→13.2V~15.0V
* SHORT CIRCUIT PROTECTION: +12V
* LEAKAGE CURRENT: 3.5MA MAX. AT NOMINAL VOLTAGE 264VAC
* SAFETY: TO MEET UL&CUL, TUV, CCC

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 