Products

1U SingleH1W-5AD0V


   

OUTPUT WATTAGE

1400W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

295x100x40(mm)

11.61x3.94x1.57(inch)

INPUT SPEC

VOLTAGE: 115 - 240 VAC FULL RANGE
FREQUENCY: 47 - 63 Hz
INPUT CURRENT: 15/10 AMPS MAXIMUM AT ANY
LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 15/30 AMPS @ 110/220VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 61000-3-2

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1 36 ±5% ±1% 50mV
+12V 2 116 ±5% ±1% 120mV
-12V 0 0.5 ±5% ±1% 120mV
+3.3V 1 31 ±5% ±1% 50mV
+5VSB 0.1 4 ±5% ±1% 50mV
* POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 210W
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 1400W FOR 180~264V
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 1200W FOR 103~132V

FEATURES

* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE –20℃~80℃
* EFFICIENCY: 82/84% TYPICAL AT 115V/230V FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* HOLD UP TIME: 17mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* OUTPUT PROTECTION: OPP / OVP / OCP / SCP
* FAN SPEED CONTROL
* SAFETY: TO MEET UL, CUL, TUV, CCC


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 