Products

Open FrameQ1H-5060V


   

OUTPUT WATTAGE

60W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

126x55x39(mm)

4.96x2.17x1.54(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:1.5A (RMS) FOR 115 VAC /
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC /
70A MAX. FOR 230 VAC

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 7 ±5% ±1% 50mV
+12V 0.1 5 ±5% ±1% 120mV
-12V 0 0.3 ±5% ±1% 120mV
+3.3V 0 6 ±5% ±1% 50mV
+5VSB 0 4 ±5% ±1% 50mV
+5V AND +3.3V TOTAL OUTPUT MAX: 30W (WITH FAN)
+5V AND +3.3V TOTAL OUTPUT MAX: 40W (WITHOUT FAN)
MAXIMUM OUTPUT POWER: 60W (FAN CFM: 8)


FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~70℃, STORAGE –20℃~80℃
* HOLD UP TIME:116mS MINIMUM AC115V @80% OF FULL LOAD
* EFFICIENCY:80%±2% TYPICAL,AT FULL LOAD 115VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS
* OVER POWER PROTECTION: 110~160% MAX
* OVER VOLTAGE PROTECTION: +3.3V→3.6V~4.3V, +5V→5.6V~6.5V, +12V→13.2V~15.0V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY : TO MEET UL, CUL, TUV, CCC
* LEAKAGE CURRENT: 3.5MA MAX. AT NOMINAL VOLTAGE 264VAC


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 