Products

Open FrameMQ1G-1060V-24


OUTPUT WATTAGE

60W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,Communication ,Networking

DIMENSION

101.6x50.8x30(mm)

4x2x1.18(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:1.5A (RMS) FOR 115 VAC /
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC /
70A MAX. FOR 230 VAC

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+24V 0.1 2.5 ± 5% ± 120mV 240mV

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~70℃, STORAGE –20℃~80℃
* HOLD UP TIME: WHEN AC SOURCE SHUTDOWN DC OUTPUT MUST BE MAINTAIN 16msec IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:85% (+/-2%) AT 115VAC/230VAC AND LOAD CONDITION: 12V/5A
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS
* OVER POWER PROTECTION: 110~160% MAX
* OVER VOLTAGE PROTECTION: +24V→26.4V~28.8V
* SHORT CIRCUIT PROTECTION: +24V
* SAFETY: TO MEET UL, CUL, TUV, CCC
* LEAKAGE CURRENT: 0.3MA MAX. AT NOMINAL VOLTAGE 264VAC


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 