【Medical】MHU2-5400V
400W
Server ,Workstation ,Storage System ,IPC ,Networking
150x140x86(mm)
5.91x5.51x3.39(inch)
VOLTAGE:100~240VAC FULL RANGE(WITH ±10% TOLERANCE) FREQUENCY:47~63HZ INPUT CURRENT:6A (RMS) FOR 115 VAC 3A (RMS) FOR 230 VAC INRUSH CURRENT:20A MAX. FOR 115 VAC 40A MAX. FOR 230 VAC
* TEMPERATURE RANGE:OPERATING 0℃~40℃ * HOLD UP TIME:16mS MINIMUM AT 115V LOAD * EFFICIENCY:80-85% TYPICAL,AT 25℃ FULL LOAD 115VAC * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms * OVER POWER PROTECTION: 120~160% MAX * OVER VOLTAGE PROTECTION: +5V→5.6V~6.5V, +3.3V→3.6V~4.3V, +12V→13.2V~15V * SHORT CIRCUIT PROTECTION: +5V、+12V、-12V、+3.3V * RESTART AFTER PRETECTION * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B * SAFETY: TO MEET UL60601, TUV EN-60601 * LEAKAGE CURRENT: 0.3mA. MAX. AT NOMINAL VOLTAGE 264VAC * REMOTE ON/OFF CONTROL: THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE,AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE. *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module