Products

Search:

HG2-5500E(500W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 90~264 VAC FULL RANGE
FREQUENCY: 47~63 Hz
INPUT CURRENT: 7A/3.5A FOR 115/230VAC
INRUSH CURRENT: 35/80 AMPS @ 115/230VAC
PFC:Up to the target of 95% @115/230VAC, full load.

HG2-6500V (24V)(500W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
1. Voltage: 100/240 VAC full range (With ±10% tolerance)

2. Frequency range will be 47hz/63hz

3. Steady-state current 8A/4A at any low/high range input voltage

4. Inrush current 20/40 Amps @ 115/230 VAC

GP2-5400V(400W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 100~240 VAC FULL RANGE
FREQUENCY: 47~63HZ
STEADY-STATE CURRENT: 6A/3A AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 20/40 AMPS @ 115/230 VAC

EHG2-5500V(500W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: DC 110~220VDC
INPUT CURRENT: 20/40 AMPS@110VDC/220VDC
STEADY-STATE CURRENT: 7A TYPICAL
INRUSH CURRENT: 20/40 AMPS @ 110VDC/220VDC

EHG2-5400V(400W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 110~220 VDC (With ±20% tolerance)
INPUT CURRENT: 20/40 AMPS@110VDC/220VDC
STEADY-STATE CURRENT: 6A TYPICAL
INRUSH CURRENT: 20/40 AMPS @ 110VDC/220VDC

HG2-5400E(400W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 90 ~ 240 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 5.5/3A FOR 115/230VAC
INRUSH CURRENT: 35/80 MAX. FOR 115/230VAC

HG2-5600E(600W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 90 ~ 240 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 8.5/4.5A FOR 115/230VAC
INRUSH CURRENT: 35/80 MAX. FOR 115/230VAC

BHG2-5300V(300W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 18 ~ 36VDC
INPUT CURRENT: 18 ~ 36VDC / 22~11 AMP (16 AMPT AT 24VDC)
INRUSH CURRENT: 50AMPS @ 24VDC

DHG2-5400V(400W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: -36 ~ -72VDC
INPUT CURRENT: -36 ~ -72VDC / 15~8 AMP (11 AMPT AT -48VDC)
INRUSH CURRENT: 50AMPS @ -48VDC

DHG2-5500V(500W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: -36 ~ -72VDC
INPUT CURRENT: -36 ~ -72VDC / 18~9 AMP (13 AMPT AT -48VDC)
INRUSH CURRENT: 50AMPS @ -48VDC

BHG2-5400V(400W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 20 ~ 36VDC
INPUT CURRENT: 20 ~ 36VDC / 30~15 AMP (22 AMPT AT 24VDC)
INRUSH CURRENT: 60AMPS @ 24VDC

DHG2-5600V(600W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: -36 ~ -72VDC
INPUT CURRENT: -36 ~ -72VDC / 21~11 AMP (16 AMPT AT -48VDC)
INRUSH CURRENT: 50AMPS @ -48VDC

 1    