Products

Search:

MP1P-5300G(300W)

DIMENSION:170x81.5x40.3(mm) / 6.69 x3.21x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:5A (RMS) FOR 115 VAC / 2.5A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30 MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

MHG2-5500G(500W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:8A (RMS) FOR 115 VAC / 4A (RMS) FOR 230 VAC
INRUSH CURRENT:20A MAX. FOR 115 VAC PER MODULE / 40A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

MP1S-6300V(300W)

DIMENSION:190x81.5x40.3(mm) / 7.48 x3.21x1.59(inch)
INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% AT 115/230VAC, FULL LOAD

MP1S-6400V(400W)

DIMENSION:250x81.5x40.3(mm) / 9.84 x3.21x1.59(inch)
INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% AT 115/230VAC, FULL LOAD

MPSM-5500V(550W)

DIMENSION:160x150x86(mm) / 6.3 x5.9x3.39(inch)
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 8A FOR 115VAC; 4A FOR 230VAC
INRUSH CURRENT: 20A MAX. FOR 115 VAC; 40A MAX. FOR 230 VAC
PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
THE POWER SUPPLY SHALL INCORPORATE UNIVERSAL POWER
INPUT WITH ACTIVE POWER FACTOR CORRECTION, WHICH
SHALL REDUCE LINE HARMONICS IN ACCORDANCE WITH
THE EN61000-3-2 STANDARDS.

MP1S-5300V(300W)

DIMENSION:190x81.5x40.3(mm) / 7.48 x3.21x1.59(inch)
INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% AT 115/230VAC, FULL LOAD

MP1S-5220V(220W)

DIMENSION:190x81.5x40.3(mm) / 7.48 x3.21x1.59(inch)
VOLTAGE:90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:3.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% AT 115/230VAC, FULL LOAD

MQ1D-5120V(120W)

DIMENSION:190x83.8x40(mm) / 7.48 x3.3x1.57(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC
70A MAX. FOR 230 VAC

MPSM-5600V(600W)

DIMENSION:160x150x86(mm) / 6.3 x5.9x3.39(inch)
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 10A FOR 115VAC; 5A FOR 230VAC
INRUSH CURRENT: 20A MAX. FOR 115 VAC; 40A MAX. FOR 230 VAC
PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
THE POWER SUPPLY SHALL INCORPORATE UNIVERSAL POWER
INPUT WITH ACTIVE POWER FACTOR CORRECTION, WHICH
SHALL REDUCE LINE HARMONICS IN ACCORDANCE WITH
THE EN61000-3-2 STANDARDS.

MHU2-5400V(400W)

DIMENSION:150x140x86(mm) / 5.91 x5.51x3.39(inch)
VOLTAGE:100~240VAC FULL RANGE(WITH ±10% TOLERANCE)
FREQUENCY:47~63HZ
INPUT CURRENT:6A (RMS) FOR 115 VAC
3A (RMS) FOR 230 VAC
INRUSH CURRENT:20A MAX. FOR 115 VAC
40A MAX. FOR 230 VAC

MHG2-6400P(400W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 100~240 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 8A/4A at any low/high range input voltage
INRUSH CURRENT: 65A MAX. FOR 115 VAC; 125A MAX. FOR 230 VAC
PFC can reach the target of 95% @230VAC,Full load.

MHG2-6350P(350W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 100~240 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 7A/3.5A AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 65A MAX. FOR 115 VAC; 125A MAX. FOR 230 VAC

 1   