DR1S2-5307V4V(300W)

DIMENSION:275.5x135x83.1(mm) / 10.85 x5.31x3.27(inch)
VOLTAGE:-36 ~ -72VDC (NORMAL -48VDC)
FREQUENCY: DC
STEADY-STATE CURRENT: 12A/6A MAXIMUN AT ANY
LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 70A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START)

S1Z2-5600K2V(600W)

DIMENSION:240x85x82(mm) / 9.45 x3.35x3.23(inch)
VOLTAGE: 90 ~ 264 VAC
FREQUENCY: 47 ~ 63 Hz.
STEADY-STATE CURRENT: 10A/5A MAX.(RMS) FOR 115/230 VAC
INRUSH CURRENT: 15A/30A MAX.FOR 115/230 VAC PER MODULE (at 25 degrees ambient cold start for each power unit)
POWER FACTOR CORRECTION: PFC CAN REACH THE
TARGET OF 95% AT 230V, FULL LOAD

S1Z2-5800K2V(800W)

DIMENSION:240x85x82(mm) / 9.45 x3.35x3.23(inch)
VOLTAGE: 90 ~ 264 VAC
FREQUENCY: 47 ~ 63 Hz.
STEADY-STATE CURRENT: 12A/6A MAX.(RMS) FOR 115/230 VAC
INRUSH CURRENT: 15A/30A MAX.FOR 115/230 VAC PER MODULE (at 25 degrees ambient cold start for each power unit)
POWER FACTOR CORRECTION: PFC CAN REACH THE
TARGET OF 95% AT 230V, FULL LOAD

S1Z2-5700K2V(700W)

DIMENSION:240x85x82(mm) / 9.45 x3.35x3.23(inch)
VOLTAGE: 90 ~ 264 VAC
FREQUENCY: 47 ~ 63 Hz.
STEADY-STATE CURRENT: 11A/5.5A MAX.(RMS) FOR 115/230 VAC
INRUSH CURRENT: 15A/30A MAX.FOR 115/230 VAC PER MODULE (at 25 degrees ambient cold start for each power unit)
POWER FACTOR CORRECTION: PFC CAN REACH THE
TARGET OF 95% AT 230V, FULL LOAD

R2K-5800K2V(800W)

DIMENSION:340x101x82(mm) / 13.39 x3.98x3.23(inch)
Input:VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63Hz.
INPUT CURRENT: 6A (RMS) FOR 230 VAC / 12A (RMS) FOR 115 VAC
INRUSH CURRENT: 30A MAX. FOR 115 VAC PER MODULE / 60A MAX. FOR 230 VAC PER MODULE
PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD

DM1K3-5I00V4V(1800W)

DIMENSION:425x54.5x126.5(mm) / 16.73 x2.15x4.98(inch)
VOLTAGE: -36 ~ -72 VDC, NORMAL -48VDC
INPUT CURRENT:47A(RMS)FOR -48VDC
INRUSH CURRENT:25A AT -48VDC (AT 25 DEGREES AMBIEND COLD START)

G1W2-5760V2V(760W)

DIMENSION:300x101.2x84(mm) / 11.81 x3.98x3.31(inch)
VOLTAGE: 90~264VAC, FULL RANGE
FREQUENCY: 47Hz~63Hz
INPUT CURRENT: 11A/5.5A MAX AT ANY LOW/HIGH INPUT VOLTAGE
INRUSH CURRENT: 40A/60A @ 115/230VAC (25℃)
POWER FACTOR CORRECTION: 95%@115/230VAC, FULL LOAD

G1W-2AE0G2(1500W)

DIMENSION:265.3x98.4x40(mm) / 10.44 x3.87x1.57(inch)
VOLTAGE: 104~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 15A (RMS) FOR 115V / 10.5A (RMS) FOR 230V
INRUSH CURRENT (PER POWER MODULE):40/80 AMPS@115/230 VAC (at 25 degrees ambient cold start for each power unit)
PFC: Up to the target of 95% @115/230VAC, full load

X1F2-5120V0V(120W)

DIMENSION:150x85x84(mm) / 5.91 x3.35x3.31(inch)
VOLTAGE: 100~240VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A(RMS)FOR 115VAC / 1A(RMS)FOR 230VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE / 70A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC can reach the target of 95% @110V full load, following the standard Of EN 61000-3-2

M1H2-5AD0V0V(1400W)

DIMENSION:450x54.5x84.6(mm) / 17.72 x2.15x3.33(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:15A(RMS)FOR 115VAC / 10A(RMS)FOR 230VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC can reach the target of 95% @110V,full load, following the standard Of EN 61000-3-2

M1H2-5AD0V0H(1400W)

DIMENSION:425x106x41.3(mm) / 16.73 x4.17x1.63(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:15A(RMS)FOR 115VAC / 10A(RMS)FOR 230VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC can reach the target of 95% @110V,full load, following the standard Of EN 61000-3-2

MTW3-5H00V3V(1700W)

DIMENSION:300x101x125(mm) / 11.81 x3.98x4.92(inch)
VOLTAGE: 100 ~ 240 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 27 / 12 amps maximum at any low/high range input voltage
INRUSH CURRENT: 40A MAX. FOR 115 VAC PER MODULE / 60A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC can reach the target of 95% @230V, full load

 1       

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module